Site Page JDJ - John Day Juvenile Fish Facility

From PTAGISWiki

Jump to: navigation, search
JDJ
Juvenile Fish Facility, USACE John Day Lock and Dam, located on the Columbia river approximately two miles east of Rufus, OR.
Googlemap: Click and drag the map to pan around. Double click to zoom and center on the cursor. More zoom controls are in the upper left corner. Zoom out to see other sites, then click on the site code for more information.


Contents

Driving Directions

  • From Tri-Cities
    • Take US-395 south
    • Take the I-82 E ramp to Pendleton/Umatilla - go 34 miles
    • Take the I-84 W ramp to Portland - go 69 miles
    • Take exit 109 to Rufus/John Day Dam Visitor Facilities - go 0.3 miles
    • Turn right at John Day Dam Ln - go two miles
    • Arrive at John Day Lock and Dam


Site Configuration

JDJ Site Configuration - click to enlarge
JDJ Site Configuration - click to enlarge












Historical Site Configurations

    JDJ: John Day Dam Juvenile
      Added new Full Flow Bypass array, with antennas 01 - 04.
         Seq. #160: From  1-Mar-07 To Present
                                  FULL FLOW BYPASS       01  02  03  04
                                  SbyC SEPARATOR GATE    A1  A2  A3  A4
                                  RIVER EXIT             81  82  83  84
                                  SAMPLE ROOM            51  52  53  54
                                  SbyC GATE              C1  C2  C3  C4
                                  SbyC EAST TANK         E1  E2
                                  SbyC WEST TANK         F1  F2
                                  SAMPLE / SbyC EXIT     91  92  93  94
                                  ADULT FISH RETURN      61  62
         Seq. #150: From  1-Mar-05 To  8-Mar-07
                                  SbyC SEPARATOR GATE    A1  A2  A3  A4
                                  RIVER EXIT             81  82  83  84
                                  SAMPLE ROOM            51  52  53  54
                                  SbyC GATE              C1  C2  C3  C4
                                  SbyC EAST TANK         E1  E2
                                  SbyC WEST TANK         F1  F2
                                  SAMPLE / SbyC EXIT     91  92  93  94
                                  ADULT FISH RETURN      61  62
         Seq. #140: From 16-Dec-99 To  1-Mar-05
                                  SbyC SEPARATOR GATE    A1  A2  A3  A4
                                  SAMPLE ROOM            51  52  53  54
                                  RIVER EXIT             81  82  83  84
                                  SbyC GATE              C1  C2  C3  C4
                                  SAMPLE / SbyC EXIT     91  92  93  94
                                  SbyC EAST TANK         E1  E2
                                  SbyC WEST TANK         F1  F2
         Seq. #130: From  2-Mar-98 To 16-Dec-99
                                  SBC SEPARATOR          00  02  04  06
                                  SUBSAMPLE              70  72  74  76
                                  RIVER EXIT ISO         20  21  22  23
                                  SBC HOLD TANK          10  12  14  16
                                  SAMPLE ROOM RIVER EX   90  91
                                  SAMPLE ROOM RIVER EX   94  96
                                  SBC HOLD TANK 2        18  1A
                                  SBC HOLD TANK 1        1C  1E
         Seq. #120: From  6-May-96 To  2-Mar-98
                                  GATEWELL 3C            F8
                                  SAMPLE ROOM            F4
                                  GATEWELL 3B            F6
         Seq. #110: From  1-Apr-95 To  6-May-96
                                  SAMPLE ROOM            F4
                                  SAMPLE BYPASS          F6
         Seq. #100: From  1-Jan-92 To  1-Apr-95
                                  SAMPLE ROOM            F4

Event Log

ftp://ftp.ptagis.org/Reports/event_log/JDJ

Pictures




PIT Tag Room



Adult Fish Return Antenna Group

Transceiver IDs 61, 62


SbyC Separator Antenna Group

Transceiver IDs A1, A2, A3, A4


3-way Rotating Gate



SbyC Gate Antenna Group

Transceiver IDs C1, C2, C3, C4


2-way Rotating Gate




SbyC East & West Tank Antenna Groups

Transceiver IDs (East) E1, E2
Transceiver IDs (West) F1, F2




Sample Room Antenna Group

Transceiver IDs 51, 52, 53, 54


Sample/SbyC Exit Antenna Group

Transceiver IDs 91, 92, 93, 94


River Exit Antenna Group

Transceiver IDs 81, 82, 83, 84



PLC

The PLC itself is located in the PIT Tag Room



Miscellaneous



Personal tools